<Error>
<ErrorNumber>15325</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: STEP : axis 2 aborted while moving
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Make sure that the red ABORT button is not pushed in. Then try selecting the
RESUME button on the workstation dialog box a few times. If this does not make
the problem go away, then Creo Service should be called.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
An ABORT command was issued from the diagnostic monitor or the red ABORT button
was pressed while the stepper motor was moving.
</text></DescriptionText>
</ServiceInformation>
<Cause>
Make sure that the red ABORT button is no pressed in. Type "mask" to see the
status of the hardware abort line. If there is an exclamation mark (!) preceding
"ABORT switch on" , then the hardware abort line is active. If the ABORT button
is not pressed in, then there is a problem with the abort switch wiring. Check
the door sensor connector (J19) on the card-cage backplane.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/mask.xml</LinkAddress><LinkTitle>Command: mask</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:02 2008 PST
</Updated>
<Links>
</Links>
</Error>